v1.01.104 ZZZZ104 — Validation of command variables into split orders with macro elements#

Summary:

This test aims to validate the consideration of control variables with macro-elements in split commands and also in monolithic commands. In both models, it is a beam (D_ PLAN) where one half is a macroelement and the other is made up of finite elements. A temperature load is affected all over the beam. The references are obtained by the same calculation without macro-elements.

Modeling A:

The calculation is done with STAT_NON_LINE. The beam is bi-embedded. It is verified that the constraints are the same as those of the reference calculation.

Modeling B:

The calculation is done in split order. The beam is embedded at one end and locked at \(X\) at the other. It is verified that the displacements are the same as those of the reference calculation.

This documentation is deliberately brief.