.. _V1.01.104: **v1.01.104** ZZZZ104 — Validation of command variables into split orders with macro elements =========================================================================================================== **Summary:** This test aims to validate the consideration of control variables with macro-elements in split commands and also in monolithic commands. In both models, it is a beam (D_ PLAN) where one half is a macroelement and the other is made up of finite elements. A temperature load is affected all over the beam. The references are obtained by the same calculation without macro-elements. Modeling A: The calculation is done with STAT_NON_LINE. The beam is bi-embedded. It is verified that the constraints are the same as those of the reference calculation. Modeling B: The calculation is done in split order. The beam is embedded at one end and locked at :math:`X` at the other. It is verified that the displacements are the same as those of the reference calculation. This documentation is deliberately brief.