4. Examples of implementation: test cases#
4.1. Thermal#
AXIS
Stationary linear thermal
TPLA07A [V4.01.007]: Thermal analysis of an orthotropic hollow cylinder subjected to various boundary conditions (imposed flow, convection, linear variation of external temperatures).
Stationary non-linear thermal
TPNA01A [V4.41.001]: Thermal analysis of a hollow cylinder subjected to convective exchange on the inner wall and to infinity radiation on the outer wall.
Transient linear thermal
TTLV01B [V4.25.001]: Transient linear thermal analysis of a solid sphere subjected to convective heat exchange.
Transient non-linear thermal
TTNA200A: non-regression test case
PLAN
Stationary linear thermal
TPLL100B [V4.02.100]: Thermal analysis of an anisotropic flat wall subjected to an imposed temperature and a flow.
Stationary non-linear thermal
TPNL300A [V4.42.300]: One-dimensional thermal analysis of a wall subjected to a temperature imposed on the inner wall and to an exchange by radiation on the outer wall (Test NAFEMS).
Transient linear thermal
TTLP100B [V4.23.100]: Calculate the linear transient thermal response of two plates separated by a gap in which heat is transferred between the walls.
Transient non-linear thermal
TTNL02A [V4.22.002]: Simulation of a liquid/solid phase change by introducing the latent heat of fusion through volume enthalpy.
Non-linear stationary thermal with mobile loading
TPLV102A [V4.04.102]: Transport of heat by convection and conduction in a square cavity.
AXIS_DIAG
Transient linear thermal
TTLV100A [V4.25.100]: Transient linear thermal analysis of a pipe assumed to be infinite in which a cold thermal shock is imposed using an exchange limit condition.
PLAN_DIAG
Transient linear thermal
TTLL100A [V4.21.100]: Transient linear thermal analysis of an infinite plane wall on which a cold thermal shock is imposed using an exchange limit condition.
Transient non-linear thermal
TTNL02C [V4.22.002]: Simulation of a liquid/solid phase change by introducing the latent heat of fusion through volume enthalpy.
4.2. Hydration#
AXIS
TTNL03B [V4.22.003]: simulation of an adiabatic test: analysis of the thermo-hydrating behavior of a fresh concrete sample immersed in a calorimeter, the setting being carried out with the release of heat.
4.3. Drying#
AXIS
HSNA102A [V7.20.102]: Validation of the calculation of concrete drying, this is an axisymmetric test case where the water concentration is applied directly to the outer wall.
AXIS_DIAG