5. Verification and validation of the law of behavior#

Here is the list of available verification and validation cases:

title

documentation

Title and purpose

SSNV232

`[V6.04.232 ===`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.04.232.pdf>

monotonic drained triaxial test (hardware point). The solution is compared to an analytical solution.

SSNV233

`[V6.04.233] ==`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.04.233.pdf>

monotonic drained torsion/drain test (hardware point).

WTNV142

`[V7.31.142] ===`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v7/v7.31.142.pdf>

monotonic undrained triaxial test (hardware point).

COMP012

`[V6.07.112] ===`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.07.112.pdf>

monotonous drained triaxial test with imposed displacement (hardware point). The solution is compared to an analytical solution. With macro command CALC_ESSAI_GEOMECA.

< https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.07.112.pdf> » COMP001 « 

`[V6.07.1`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.07.112.pdf>`01`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.07.112.pdf>``_ `=`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.07.112.pdf>

Verification of elastoplastic behaviors on a material point for a change of units and after rotating the reference frame.

SSNP104

`[V6.03.104] =`_ < https://www.code-aster.org/V2/doc/default/fr/man_v/v6/v6.03.104.pdf>

under monotonous loading: rigid sole placed on a homogeneous ground. Comparison with the results obtained with the original Mohr-Coulomb elastoplastic law and with analytical results. Verification and validation versions