Reference solution ===================== Calculation method used for the reference solution -------------------------------------------------------- This test is taken from the software validation manual POSTDAM version 1.0. The reference solutions are given in this document. Benchmark results ---------------------- The counting of the elementary cycles by the RAINFLOW method leads to: .. csv-table:: "Nb_Cycl = 12", "Cycle 1", "Vale_Min:", "5. ", "Vale_Max:", "11." "", "Cycle 2", "Vale_Min:", "3. ", "Vale_Max:", "4." "", "Cycle 3", "Vale_Min:", "6. ", "Vale_Max:", "10." "", "Cycle 4", "Vale_Min:", "1. ", "Vale_Max:", "12." "", "Cycle 5", "Vale_Min:", "4. ", "Vale_Max:", "8." "", "Cycle 6", "Vale_Min:", "4. ", "Vale_Max:", "6." "", "Cycle 7", "Vale_Min:", "4. ", "Vale_Max:", "7." "", "Cycle 8", "Vale_Min:", "2. ", "Vale_Max:", "9." "", "Cycle 9", "Vale_Min:", "5. ", "Vale_Max:", "9." "", "Cycle 10", "Vale_Min:", "3. ", "Vale_Max:", "4." "", "Cycle 11", "Vale_Min:", "2. ", "Vale_Max:", "10." "", "Cycle 12", "Vale_Min:", "1. ", "Vale_Max:", "12." Uncertainty about the solution --------------------------- Analytical solution. Bibliographical references --------------------------- 1. Validation manual POSTDAM 1.0. Fournier I., Vatin E. HP-14/93/016/B.