2. Modeling#
The objective of this modeling is to model a non-regression calculation for a single relative humidity (HR = 0.805).
2.1. Characteristics of modeling#
2.2. Modeling result#
The constraints field “SIEF_NOEU” is calculated to be able to recover the effective constraint in the X direction (“SIXX”) on any node (here the N2 node) and for the final moment.
The values of “SIXX” are compared to the analytical value \(-d{\mathrm{\sigma }}_{p}\) for HR=0.805 presented in section 2.2 and are shown in the table below.
HR tested |
\(-d{\mathrm{\sigma }}_{p}\) (Mpa) (analytics) |
SIXX (MPa) |
\((\text{\%})\) gap |
0.805 |
-7.950 |
-7.258 |
8.7 |
Table 2.2-1- Effective stress comparison