.. _V7.33.107: **v7.33.107** WTNA107 - Axisymmetric modeling of the heating of a water-saturated element ========================================================================================== **Summary:** This test represents the heating of an element saturated with water taking into account the mechanics. This is a test case of non-regression without physical reality. It makes it possible to test coupled thermo-hydro-mechanical models such as: AXIS_THM * in monophasic water (LIQU_SATU). This is the axisymmetric version of test case WTNL101. Modeling A: * Modeling AXIS_THM * Coupling: law LIQU_SATU Modeling B: * Modeling AXIS_THMD (lumped) * Coupling: law LIQU_SATU C modeling: * Modeling AXIS_THMS (selective) * Coupling: law LIQU_SATU This documentation is deliberately brief.