4. B modeling#
4.1. Characteristics of B modeling#
Same modeling as in A selectively, model D_ PLAN_THH2MS.
4.2. Tested sizes and results#
We recall that the temperature from the thermal calculation corresponds to the dry air pressure from our thermo-hydro-mechanical calculation. Since the vapour pressure is constant, we have:
\(X\) ( \(m\) ) |
Time ( \(s\) ) |
\(\mathit{PRE2}\) Aster |
\(\mathit{PRE2}\) thermal calculation |
Relative error ( \(\text{\%}\) ) |
0.2 |
3.00E+009 |
1.128E4 |
1.120E4 |
0.74 |
0.2 |
5.00E+009 |
1.227E4 |
1.224E4 |
0.25 |