F modeling ============== Characteristics of F modeling ------------------------------------- It is the same modeling and the same mesh as the E modeling but in AXI. The models AXI_THH2MS, AXI_HH2MS,, AXI_THH2S and AXI_HH2S are tested successively. Tested values and results ---------------------------- As before, it is verified that the water flow ('FH11X' + 'FH12X' recovered by SIEF_NOEU) obtained on the taxation edge corresponds to its analytical expression, namely :math:`q_{w}^{ext}{.}n= \alpha.\rho_{vp}.\left( exp\left[ \frac{Pc.M_{H2O}}{\rho_{l}.R.T}\right] -{HR}^{ext} \right)`. A tolerance of 10% is allowed due to the size of the mesh and the error generated by the interpolation at the node. +------------------------+--------------------------+-----------------+----------------+ |**Points** :math:`(x,y)`|**Time (** :math:`s` **)**|'FH11X' + 'FH12X'|Analytical value| +------------------------+--------------------------+-----------------+----------------+ |:math:`(\mathrm{0,2};0)`|1800 |7.3754E-09 |8.09e-09 | +------------------------+--------------------------+-----------------+----------------+ For reasons of saving time, models other than AXI_THH2MS will only be tested for 60 s. We check that the pressures at 60 s are all the same regardless of the models. +------------------------+--------------------------+-----+ |**Points** :math:`(x,y)`|**Time (** :math:`s` **)**|PRE1 | +------------------------+--------------------------+-----+ |:math:`(\mathrm{0,2};0)`|1800 |10019| +------------------------+--------------------------+-----+