3. B modeling#

3.1. Characteristics of modeling#

Modeling A is done in sub-integrated 3D with a second gradient (3D_ HM_SI_DIL), using STAT_NON_LINE.

The aim of this modeling is to verify the use of the second gradient in 3D_ HM_SI.

3.2. Tested sizes and results#

3.2.1. Tested values#

It is a non-regression test.

\(t=12\mathit{sec}\)

Reference

Relative Error

Absolute Error

\({\mathrm{\sigma }}_{\mathit{xx}}\)

-30777.02

3.E-4

\(p\)

-19226.58

5.E-4

\({\mathrm{\epsilon }}_{v}^{p}\)

1.262378E-05

1.E-6

\({\mathrm{\epsilon }}_{d}^{p}\)

2.270058E-05

1.E-6

Table 3.2.1-1: Validation of results for modeling A