3. B modeling#
3.1. Characteristics of modeling#
Modeling A is done in sub-integrated 3D with a second gradient (3D_ HM_SI_DIL), using STAT_NON_LINE.
The aim of this modeling is to verify the use of the second gradient in 3D_ HM_SI.
3.2. Tested sizes and results#
3.2.1. Tested values#
It is a non-regression test.
\(t=12\mathit{sec}\) |
Reference |
Relative Error |
Absolute Error |
\({\mathrm{\sigma }}_{\mathit{xx}}\) |
-30777.02 |
3.E-4 |
|
\(p\) |
-19226.58 |
5.E-4 |
|
\({\mathrm{\epsilon }}_{v}^{p}\) |
1.262378E-05 |
1.E-6 |
|
\({\mathrm{\epsilon }}_{d}^{p}\) |
2.270058E-05 |
1.E-6 |
Table 3.2.1-1: Validation of results for modeling A