v7.31.135 WTNV135 - Drained triaxial test: models LETK, LKR and NLH_CSRM#

Summary

This test makes it possible to validate models LETK, LKR, and NLH_CSRM in the context of hydromechanical modeling. It is a triaxial test under drained conditions.

For reasons of symmetry, only one eighth of a sample subjected to a triaxial test is interested in.

The lockdown level is \(5\mathit{MPa}\).

Modeling A: Integration of the model through an explicit diagram, with classical modeling: model LETK.

Modeling B: Integration of the model by implicit diagram whose Jacobian matrix is obtained by disturbance, with classical modeling: model LETK.

C modeling: Integration of the model by implicit schema whose Jacobian matrix is obtained analytically, with classical modeling: model LETK.

D modeling: Integration of the model through an explicit diagram, with sub-integrated modeling: model LETK.

Modeling F: Integration of the model by implicit diagram whose Jacobian matrix is obtained by disturbance, increasing temperature 0°C-100°C (AFFE_CHAR_MECA): model LKR.

G modeling: Integration of the model by implicit diagram whose Jacobian matrix is obtained analytically, increasing temperature 0°C-100°C (AFFE_CHAR_MECA): model LKR.

H modeling: Validation of model NLH_CSRM, ambient temperature, international unit system.