Summary of results ====================== The following curves represent the various comparisons between *Code_Aster* and GEFDYN, in terms of isotropic pressure (Figure), plastic volume deformation (Figure) and deviatory work hardening coefficients (Figure). .. image:: images/1000000000000291000001EF02D2ABA6D8DD60BA.png :width: 6.8437in :height: 5.1563in .. _RefImage_1000000000000291000001EF02D2ABA6D8DD60BA.png: **Figure** 4-a **:** **Cyclic undrained triaxial test* * *(Plan* :math:`P\mathrm{-}Q` *): comparison between Code_Aster solutions and* *GEFDYN* * *for a consolidation pressure of* :math:`30\mathrm{kPa}`\ *.* .. image:: images/10000000000002160000018368D810FA79F958DC.png :width: 5.5626in :height: 4.0311in .. _RefImage_10000000000002160000018368D810FA79F958DC.png: **Figure** 4-b **:** *Plastic volume deformation as a function of the stress deviator: comparison between Code_Aster solutions and* :math:`\text{GEFDYN}` *\* . ** .. image:: images/10000000000002230000018153CE4395482E19D1.png :width: 5.698in :height: 4.0102in .. _RefImage_10000000000002230000018153CE4395482E19D1.png: **Figure** 4-c **: monotonic deviation radius as a function of the constraint deviator: comparison between the results of Code_Aster and** GEFDYN **.**