.. _V7.20.102: **v7.20.102** HSNA102 - Validation of drying laws on a cylindrical concrete test piece =============================================================================================== **Summary:** This test case is intended to validate the calculation of concrete drying, developed in the *Code_Aster* nonlinear thermal operator. Here we test the various diffusion laws available in *Code_Aster*, namely SECH_GRANGER, SECH_MENSI, SECH_BAZANT and SECH_NAPPE. However, the possible temperature dependence of the models is not tested. This is an axisymmetric test case where the water concentration is applied directly to the outer wall. The results are compared with a numerical solution of the equations using Scilab. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Probl_me_de_r_f_rence Solution_de_r_f_rence Mod_lisation_A Mod_lisation_B Mod_lisation_C R_sultats_de_la_mod_lisation_C Mod_lisation_D R_sultats_de_la_mod_lisation_D Synth_se_des_r_sultats