.. _V7.03.108: **v7.03.108** HPLV108 — Verification of the homogenized parameters of a pierced plate ==================================================================================== **Summary:** The objective of this test is to verify some of the parameters calculated by the CALC_MATE_HOMO command on a pierced plate. The reference values come from R&D studies conducted in 84 and 93. Modeling A calculates the properties of an MASSIF equivalent, modeling B of an equivalent PLAQUE, and modeling C a homogeneous PLAQUE. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: reference reference_massif modelisations modA modB modC results bibliographie