D modeling ============== Characteristics of modeling ----------------------------------- The 3D modeling is carried out on a 3D hardware point with STAT_NON_LINE. The difference compared to modeling B is the calculation of the initial state by a thermal loading. To bring the sample to the initial isotropic stress :math:`{P}_{0}=10\mathit{kPa}`, the sample is brought from 20° to 30° Celsius. The movements of the sample are blocked, so that thermal expansion brings the sample into compression. We get: :math:`{\mathrm{\sigma }}_{0}=\frac{E}{9\left(1-2\mathrm{\nu }\right)}\mathrm{\alpha }\mathrm{\Delta }T={P}_{0}` Let the following value for the coefficient of thermal expansion be: :math:`\mathrm{\alpha }=\frac{9\left(1-2\mathrm{\nu }\right){P}_{0}}{E\mathrm{\Delta }T}` Tested sizes and results ------------------------------- Tested values ~~~~~~~~~~~~~~~~ The solutions are post-treated at point :math:`C`, in terms of: * vertical constraint :math:`{\mathrm{\sigma }}_{\mathit{zz}}`; * horizontal deformation :math:`{\mathrm{ϵ}}_{\mathit{xx}}`; * :math:`{e}^{P}=\Vert {e}^{P}\Vert` deviatoric plastic deformation norm They are compared to an analytical solution (described in the next paragraph) in terms of *maximum difference between* :math:`t=0` *and* :math:`t=20`. The results are summarised in the following tables: :math:`Q=\sqrt{\frac{1}{2}\underline{\underline{s}}\mathrm{:}\underline{\underline{s}}}[\mathit{Pa}]` +----------------------------------------+---------------------------------------------+ |Variable |Absolute deviation | Code_Aster − Analytics || +----------------------------------------+---------------------------------------------+ |:math:`{\mathrm{\sigma }}_{\mathit{zz}}`|0 | +----------------------------------------+---------------------------------------------+ |:math:`{\mathrm{ϵ}}_{\mathit{xx}}` |3.10-5 | +----------------------------------------+---------------------------------------------+ |:math:`{e}^{P}` |1.333 10-5 | +----------------------------------------+---------------------------------------------+ Comments ~~~~~~~~~~~~ The difference with the analytical solution is very small.