5. C modeling#
5.1. Characteristics of modeling and meshing#
Meshing is identical to modeling A. The study is divided into 2 steps.
In the first, the tension is calculated by taking into account only the losses due to friction and anchor recoil. All cables are stretched simultaneously.
In the second phase, it is assumed that cable 5 is broken. The new voltage profile is applied.
5.2. Tested sizes and results#
The voltage profile (component N) in the cable 5 is tested, more precisely the minimum value and the sum of the Ns over the entire cable. More exactly, we compare the values obtained at the end of DEFI_CABLE_BPet at the end of CALC_PRECONT and we compare them with the values of the voltage supplied at the input.
Component |
Table |
Reference Type |
Reference Value [\(N\) ] |
Tolerance ( \(\text{\%}\) ) |
|
“MIN” |
“tensc5nv” |
“AUTRE_ASTER” |
“” |
561.23848763760 |
|
“SOMM” |
“tensc5nv” |
“AUTRE_ASTER” |
“” |
957773249,63245 |
|
“MIN” |
“tensc5f” |
“AUTRE_ASTER” |
“” |
561,23848763760 |
3* 10-4% |
“SOMM” |
“tensc5f” |
“AUTRE_ASTER” |
“” |
957773249,63245 |
|