.. _V6.04.211: **v6.04.211** SSNV211 - Drained triaxial test with model VISC_DRUC_PRAG =========================================================================== **Summary** This test makes it possible to validate model VISC_DRUC_PRAG based on the elastoplastic Drucker-Prager model. Creep is taken into account by a Perzyna power law. It is a triaxial test in pure mechanics or under drained conditions. The calculations are carried out only on the solid part of the soil without hydromechanical coupling. A lockdown level of :math:`5\mathit{MPa}` is being applied. For reasons of symmetry, only one eighth of a sample subjected to a triaxial test is interested in. The modeling is axisymmetric. It is a non-regression test. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Probl_me_de_r_f_rence Mod_lisation_A Synth_se_des_r_sultats