Benchmark solution ===================== Calculation method used for reference solutions ---------------------------------------- The reference was obtained by comparing the solutions between models A and B. For modeling C, it is only non-regression. Reference quantity --------------------- * Constraint :math:`\mathrm{SIYY}` at point :math:`G` Benchmark result --------------------- A and B modeling: +----------------------------------+-----------+---------+-----------------+ |Grandeur |jiffy |Point |Reference | +----------------------------------+-----------+---------+-----------------+ |:math:`\mathrm{SIYY}(\mathrm{Pa})`|:math:`40` |:math:`G`|:math:`632.29325`| + +-----------+---------+-----------------+ | |:math:`240`|:math:`G`|:math:`761.7493` | +----------------------------------+-----------+---------+-----------------+