.. _V6.04.135: **v6.04.135** SSNV135 - Drained triaxial test with model CJS (level 1) ============================================================================ **Summary** This test validates level 1 of model CJS. It is a triaxial test under drained conditions. Three levels of confinement are simulated: :math:`100`, :math:`200`, then :math:`400\mathrm{kPa}`. For reasons of symmetry, only one eighth of a sample subjected to a triaxial test is interested in. The results obtained with model CJS1 are compared with the analytical solution. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Probl_me_de_r_f_rence Solution_de_r_f_rence Mod_lisation_A Synth_se_des_r_sultats