.. _V6.04.131: .. image:: images/1000020100000328000002242D0BFE062EE3E2D4.png :width: 5.1008in :height: 3.4591in .. _RefImage_1000020100000328000002242D0BFE062EE3E2D4.png: Figure 1.1-1: **G** geometry **of the tube** **v6.04.131** SSNV131 —Straight cracked elasto-plasticity pipe under combined loading ======================================================================================= **Summary:** The problem under consideration is a cracked straight tube with a semi-elliptical longitudinal defect in the inner skin. The straight pipe is subjected to a loading of combined pressure and bending moment. This test makes it possible to calculate the local energy restoration rate at the bottom of the crack by the G-theta method (command CALC_G) The local energy restoration rate is calculated according to the interpolation LINEAIRE. The integration rings are defined by the data of the number of layers (NB_COUCHE_INF and NB_COUCHE_SUP). The value of G at the bottom of a crack is compared to a score used for the validation of simplified methods in fracture mechanics. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Probl_me_de_r_f_rence Solution_de_r_f_rence Mod_lisation_ Synth_se_des_r_sultats