Summary of results ====================== It should be noted that the reference solution is not an exact solution and that it does not apply, in general, in the case of bi-materials. Moreover, the calculations are carried out in non-linear elasticity on a crack; From a point of view, it would be appropriate to perform the elastoplasticity calculations on a notch. Modeling A (degree 1) gives results in accordance with those of the reference. Modeling B (degree 2) reveals a difference of around :math:`\text{8\%}` on the value of :math:`G`. It can be noted that crowns far from the crack provide more accurate and more stable results than those close to the bottom of the crack.