.. _V6.03.124: **v6.03.124** SSNP124 — Drained biaxial test with DRUCK_PRAGER softening behavior ========================================================================================== **Summary:** This test case makes it possible to implement a drained biaxial test on two different models during a non-linear calculation. This makes it possible to highlight the effect of the type of negative, parabolic or linear work hardening in the case of the D_ PLAN model. Modeling A * "DRUCK_PRAGER" type model with linear negative work hardening for :math:`2\mathrm{Mpa}` confinement. * model D_ PLAN with QUAD4 meshes. Modeling B: * "DRUCK_PRAGER" type model with parabolic negative work hardening for :math:`2\mathrm{MPa}` confinement. * model D_ PLAN with QUAD4 meshes. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Probl_me_de_r_f_rence_ Solution_de_r_f_rence Mod_lisation_A Mod_lisation_B Synth_se_des_r_sultats