2. Benchmark solution#
2.1. Calculation method#
The reference result was obtained by calculating the floor envelope spectrum (level 1) of the building using conventional commands, commands grouped under command MACR_SPECTRE.
2.2. Benchmark results#
The envelope floor spectrum obtained for damping equal to \(\mathrm{0,05}\) at the various frequencies is presented below.
Frequency \((\mathit{Hz})\) |
Acceleration \((m/{s}^{2})\) |
\(\mathrm{0,1}\) |
5.10535E-03 |
\(\mathrm{0,2}\) |
1.62051E-02 |
\(\mathrm{0,3}\) |
2.55750E-02 |
\(\mathrm{0,41}\) |
3.53812E-02 |
\(\mathrm{0,52}\) |
4.53316E-02 |
\(\mathrm{10,0}\) |
2.89311E+00 |
\(\mathrm{15,0}\) |
1.87495E+01 |
\(\mathrm{20,0}\) |
6.32936E+00 |