5. Summary of results#

The results obtained are satisfactory, the maximum difference is 2.5% less than the tolerance set initially (5%) (the reference solution is obtained graphically).

This test made it possible to test in linear transient, modeling PLAN, the commands:

  • DEFI_MATERIAU associated with the keyword THER_ORTH, making it possible to define the characteristics of an orthotropic material,

  • AFFE_CARA_ELEM associated with the MASSIF keyword, allowing to define orthotropy axes.