5. Summary of results#

The results obtained are satisfactory, the maximum difference is — 0.15%.

The observation points, located at \(x=0.05\) and belonging to cells of different types, have the same result.

This test made it possible to test the AFFE_CHAR_THER_F command with the SOURCE operand using a linear transient (modeling PLAN).