v4.05.303 TPLP303 - Temperature distribution in the section of a chimney pipe#

Summary:

This test is the result of the independent validation of version 3 in linear stationary heat.

This is a \(\mathrm{2D}\) plane problem represented by seven models, each mixing several types of elements.

The features tested are as follows:

  • flat thermal element,

  • volume thermal element,

  • limit condition: convection.

The advantage of the test lies in the mixture of different elements.

The results are compared with an analytical solution.