5. Summary of results#
The two models performed (AXIS_FOURIER and 3D) give excellent results, the maximum difference is \(-0.006\text{\%}\) for both models
This test made it possible to test the CREA_CHAMP command in AXIS_FOURIER with the following operands:
COMB_FOURIER to calculate the temperature at a given angle,
ASSE to perform a linear combination of modes 0 and 1.