1. Reference problem#
1.1. Geometry#
Axisymmetric
A |
B |
C |
C |
D |
M |
|
r |
2.7182 |
2.7182 |
1.8591 |
|||
z |
0.1 |
0.1 |
0.025 |
1.2. Material properties#
Electrical characteristic: electrical conductivity \(\sigma =1.{\Omega }^{-1}{m}^{-1}\)
Thermal characteristics: \(\lambda ={2.10}^{-2}W/m°C\) \({C}_{P}=0.\)
1.3. Boundary conditions and loads#
Electrical calculation:
\(\begin{array}{cc}\mathrm{j.n}=-10& \text{sur}\mathrm{DA}\\ \mathrm{j.n}=3.6787944& \text{sur}\mathrm{BC}\end{array}\)
Thermal calculation
\(T=0.\) out of \(\mathrm{DA}\)
\(T=0.\) out of \(\mathrm{BC}\)
\(\mathrm{FLUX}=0.\) out of \(\mathrm{AB}\)
\(\mathrm{FLUX}=0.\) out of \(\mathrm{CD}\)
1.4. Initial conditions#
Stationary calculation.