Summary of results ====================== The modeling gives results where a value (out of 10) exceeds the tolerance set initially :math:`(5\text{\%})`. The maximum difference obtained is :math:`-6.10\text{\%}`, it is located at the lowest reference value. In this test, *Code_Aster* applies an "overload law" which in this case consists in taking into account the last limit condition entered. The order in which the temperatures imposed are assigned therefore has a major influence on the results obtained. The calculations were done in :math:`\text{°}C`. Determining the difference, considering the temperatures in :math:`\text{°}F`, gives a maximum value that is very different from that obtained in :math:`\text{°}C`. A calculation carried out with the software NISA gives results identical to those of Code_Aster (verified in the case where the temperature imposed at point L is :math:`4.44\text{°}C`). The quality of the results could be improved by performing a finer mesh, the problem of overload would still be present, but the area of influence of the temperature imposed at point L would be weaker. The results are considered to be acceptable taking into account the modeling carried out (mesh and unit system, overload law).