v3.04.163 RCCM15 - Validation of POST_RCCM in B3600#
Summary:
This test makes it possible to validate the fatigue calculation option according to the code RCC -M (B3600). The constraints are not calculated but taken from tables.
This test includes two models, which differ in the way in which thermal transients are taken into account:
the first performs the calculation of the two thermal transients on two axisymmetric sections of the same diameter and thickness as the straight pipes and the elbow,
the second reads directly the values from a temperature reading on the thermal calculation of the elbow, previously modelled in \(\mathrm{3D}\) by the MMC department.
The reference solution is numerical (code SYSPIPE and note EDF/MMC).