v3.04.163 RCCM15 - Validation of POST_RCCM in B3600#

Summary:

This test makes it possible to validate the fatigue calculation option according to the code RCC -M (B3600). The constraints are not calculated but taken from tables.

This test includes two models, which differ in the way in which thermal transients are taken into account:

  • the first performs the calculation of the two thermal transients on two axisymmetric sections of the same diameter and thickness as the straight pipes and the elbow,

  • the second reads directly the values from a temperature reading on the thermal calculation of the elbow, previously modelled in \(\mathrm{3D}\) by the MMC department.

The reference solution is numerical (code SYSPIPE and note EDF/MMC).