Modeling A ============== Characteristics of modeling ------------------------ No thermal or mechanical calculation is carried out in this test: the stress reading tables are directly provided to operator POST_RCCM. Results of type ZE200a are analyzed for options SN and FATIGUE. Tested sizes and results ------------------------------ On this simple test case, all the results tested are in agreement with the reference solution with an accuracy of :math:`{10}^{-4}`%. * for the calculation of Sn, Sp, Salt and the use factor, * for a pipe junction, * with and without an earthquake.