Benchmark solution ===================== Calculation method ----------------- The reference solution is obtained by the Nastran software. Reference quantities and results ----------------------------------- The displacement is recorded on various nodes including the discreet one. .. csv-table:: "**Identification**", "**Reference value**" "NOEUD ='N000007', NOM_CMP ='DX', NOEUD ='N000006', NOM_CMP ='DY', NOEUD ='N000002', NOM_CMP ='DZ', NOEUD ='N000002', NOM_CMP ='DX', NOEUD ='N000002', NOM_CMP ='DY', NOEUD ='N000007', NOM_CMP ='DZ', NOEUD ='N000009', NOM_CMP ='DX', NOEUD ='N000009', NOM_CMP ='DY', NOEUD ='N000009', NOM_CMP ='DZ', NOEUD ='N000009', NOM_CMP =' DRX ', NOEUD ='N000009', NOM_CMP =' DRY ', NOEUD ='N000009', NOM_CMP =' DRZ ',", "2.09288E-05 -7.29517E-06 0.00000E+00 -6.23697E-06 -2.45257E-05 -2.79835E-05 8.655062E-05 3.349630E-05 -7.131093E-05 -1.834213E-05 1.222809E-05 -1.493772E-05" Uncertainties about the solution ---------------------------- None