6. D modeling#

6.1. Characteristics of modeling#

MEDKTR3 (modeling DKT)

_images/Object_47.svg

6.2. Characteristics of the mesh#

Number of knots: 121

Number of meshes and types: 200 TRIA3

6.3. Tested values#

Critical loads

Identification

Reference Type

Reference

Tolerance %

mode 1

“ANALYTIQUE”

3.79600E+02

0.01

mode 2

“ANALYTIQUE”

1.05444E+03

2.0

mode 3

“ANALYTIQUE”

2.56609E+03

5.0