Benchmark solution ===================== The result of the macro command POST_NEWMARK is compared to other methods of estimating the safety factor, based on the Potgieter results [:ref:`1 <1>`]: * Slice method using the SLOPE /W software **Enhanced Limit Equilibrium* by SIGMA /W and SLOPE /W software * C-phi reduction by the PLAXIS 2D software. The approach used by the POST_NEWMARK macro command is similar to the *Enhanced Limit Equilibrium* method and the results should be as close as possible to this method. The reference values obtained by Potgieter [:ref:`1 <1>`] for these three methods are as follows: * Slice method: FS = 1.73 **Enhanced Limit Equilibrium*: FS = 1.82 * c-phi reduction: FS = 1.72