.. _V3.02.100: **v3.02.100** SSLP100 - Stock in static substructure ========================================================== **Summary:** This test case validates static substructuring, consisting in the condensation of stiffness matrices and loads. The plane modeling of a structure with linear behavior is carried out. 2 Modelings: * A: "ordinary" plan model: this is the reference solution. * B: model with substructures. Interest: * substructuring at two levels, * rotation of macro-elements and loads (followers or not), * calculation of fields within macro elements. B's results are the same as A except :math:`{10}^{\mathrm{-}5}`. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Probl_me_de_r_f_rence Solution_de_r_f_rence Mod_lisation_A Mod_lisation_B Synth_se_des_r_sultats