6. D modeling#
6.1. Characteristics of modeling#
20 items POU_D_E
6.2. Characteristics of the mesh#
Number of knots: 21
Number of meshes and types: 20 SEG2
6.3. Tested sizes and results#
Load case |
Reference |
Tolerance (%) |
1 |
1.088 |
0.12 |
2 |
0.680 |
0.025 |
We are also testing the management of the DEFI_LIST_INST “INSTABILITE” event. More exactly, this event occurs because the critical load coefficient crosses the value \(1\) and this must therefore trigger the associated action, always defined under DEFI_LIST_INST.
Since we want to continue the calculation despite this detected instability, we specify:
ACTION = “CONTINUE”.