4. Summary of results#

Appropriate modeling (frequencies and natural modes within \(\text{2\%}\)) with a fine mesh.

A calculation performed on a coarse mesh (12 cells) shows larger differences with the reference solution. This is mainly due to the way in which fashions are standardized.