Summary of results ====================== For modeling A, the results obtained both in movement and in speed have an absolute error much less than :math:`\text{1 \%}` compared to the analytical solution. The Newmark integration diagram is more accurate than the Euler diagram. In addition to critical damping (B modeling), the Fu-Devogelaere integration diagram is extremely accurate (no error compared to the reference solution). :math:`\text{1 \%}` The 2nd order adaptive time step diagram also gives results with a very low percentage of error. For very low damping (modeling C), better precision will be noted for the Euler-type integration diagram than for a Newmark type diagram. For the latter, the error increases over time but is still less than :math:`\text{1 \%}`.