.. _V1.01.403: **v1.01.403** ZZZZ403 - Validation of the use of POST_LIQUEFACTION on a 2D dam case =================================================================================================== **Summary:** This test validates the use of macro command POST_LIQUEFACTION. [:ref:`U4.84.44 `], which calculates a criterion for detecting soil liquefaction. The four formulas associated with the criterion are tested, Modeling A: carrying out a comparative test between a fictional field on a dam and a Code_Aster calculation using the POST_LIQUEFACTION macro command. It was chosen to take extremely simple values for the fields in order to verify the analytical values obtained. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Mod_lisation_A Conclusion