U modeling ============== Characteristics of modeling ----------------------------------- It is the modeling of a complete problem in non-linear thermics used as a basis for A, B, C, D, D, I, I, K, L, and O models. Characteristics of the mesh ---------------------------- The mesh contains 27 elements of type HEXA8. Tested sizes and results ------------------------------ The value of the temperatures obtained in non-regression is tested: .. csv-table:: "**Location**", "**Instant**", "VALE_REFE **,"** (**TEMP**) **", "** PRECISION **" "Node A in :math:`({1,0,3})` "," :math:`t=1s` "," "," :math:`{29.9053048593}°C` ", "6.0E-5" "Node A in :math:`({1,0,3})` "," :math:`t=4s` "," "," :math:`{139.462715634}°C` ", "2.0E-5" "Node A in :math:`({1,0,3})` "," :math:`t=7s` "," "," :math:`{567.08693147}°C` ", "7.0E-6" "Node A in :math:`({1,0,3})` "," :math:`t=10s` "," "," :math:`{999.349943608}°C` ", "6.0E-6" notes --------- We cannot say anything in absolute terms about the precision of these values because we are testing values of non-regression.