E modeling ============== This test reproduces bench EPX bm_str_lcab_frot. It validates the use of friction cables in EPX without damping. Friction material ---------------------- The material BPEL_ACIER is assigned to the cable for Code_Aster and to the friction discretes for EPX with the following parameters: .. csv-table:: "FROT_LINE ", "0.018" "FROT_COURB ", "0.38" These coefficients correspond to twice the regulatory friction coefficients of type TICC (Strands Injected with Cement Grout). Tested sizes and results ------------------------------ .. csv-table:: "**Node**", "**Component**", "**Moment (s)**", "**Reference Value (m)**", "**Tolerance**" ":math:`\mathit{NY10}` "," :math:`\mathit{DX}` ", "0.11"," :math:`2.27750E-01` "," :math:`1.E-3`" ":math:`\mathit{NY10}` "," :math:`\mathit{DX}` ", "0.4"," :math:`2.37959E-01` "," :math:`1.E-3`" .. csv-table:: "**Mesh**", "**PG**", "**Component**", "**Component**", "**Instant (s)**", "**Reference Value (m)**", "**Tolerance**" ":math:`\mathit{MCAY10}` ", "1"," :math:`N` ", "0.11"," :math:`40510650.0` "," :math:`1.E-3`" ":math:`\mathit{MCAY10}` ", "1"," :math:`N` ", "0.4"," :math:`38661900` "," :math:`1.E-3`"