D modeling ============== But --- The aim of this test is to validate the use of 3D modeling on support mesh TETRA4 in CALC_EUROPLEXUS. It is already possible in EPX not to read an initial stress state on the corresponding elements. We will therefore also use and validate this feature which was immediately activated in CALC_EUROPLEXUS. Description ----------- This test is the equivalent of test case EPX bm_tetr_ini_med_cont. Same steps as modeling C. Principle of validation ---------------------- Comparison with the initial state. Tested values --------------- .. csv-table:: "**Node**", "**Component**", "**Reference Type**", "**Reference Value**", "**Tolerance**" "N2"," :math:`\mathit{DX}` ", "'AUTRE_ASTER'", "2.19188002660453E-033", "''", "''", "''", "" 1E-6" "N5"," :math:`\mathit{DY}` ", "'AUTRE_ASTER'", "''", "5.81721432580442E-04", "1E-6" "N5"," :math:`\mathit{DZ}` ", "'AUTRE_ASTER'", "-2.43970568218930E-03", "''", "''", "1E-6" .. csv-table:: "**Mesh**", "**Component**", "**Point**", "**Reference Type**", "**Reference Value**", "**Tolerance**" "M1"," :math:`\mathit{SIXX}` ", "1", "'AUTRE_ASTER'", "''", "1.33476658397901E+07", "1E-6" "M1"," :math:`\mathit{SIYY}` ", "1", "'AUTRE_ASTER'", "''", "1.32759870309648E+07", "1E-6" "M1"," :math:`\mathit{SIZZ}` ", "1", "'AUTRE_ASTER'", "''", "3.09327863977736E+07", "1E-6" "M2"," :math:`\mathit{SIXY}` ", "1", "'AUTRE_ASTER'", "''", "1.20735966805089E+07", "1E-6" "M2"," :math:`\mathit{SIXZ}` ", "1", "'AUTRE_ASTER'", "''", "2.29556551673508E+07", "1E-6" "M2"," :math:`\mathit{SIYZ}` ", "1", "'AUTRE_ASTER'", "''", "-7.54657118237435E+06", "1E-6"