.. _V1.01.216: **v1.01.216** ZZZZ216 — Weak coupling 3D code_saturne-code_aster ================================================================== **Summary:** This test validates the weak 3D*code_Saturne*-*code_aster* coupling. The aim is to model a mechanical calculation with a subsequent pressure coming from a fluid calculation. Here is what the different models test: - A: purely mechanical reference calculation. - B and C: *code_aster*-*code_aster* coupling with interface-compliant meshes on 2 and 4 MPI. - D and E: coupling *code_aster*-*code_aster* with meshes that do not conform to the interface on 2 and 4 MPI. - F: coupling *code_saturne*-*code_aster* with meshes conforming to the interface on 4 MPI. - G: *code_saturne*-*code_aster* coupling with meshes that do not conform to the interface on 4 MPI. .. toctree:: :hidden: self .. toctree:: :maxdepth: 2 :numbered: Probleme_de_reference Solution_de_reference Synthese_des_resultats