D modeling ============== Characteristics of modeling ----------------------------------- No thermal or mechanical calculation is carried out in this test: the stress reading tables are directly provided to operator POST_RCCM. The B3200 results are analyzed for option EFAT. Tested sizes and results ------------------------------ On this simple test case, all the results tested are in agreement with the reference solution: * for the calculation of Sn, Sp, FEN; * with and without an earthquake * with option TYPE_RESU =' DETAILS '. Analytical solution with less than :math:`{10}^{-4}` percent accuracy.