C modeling ============== Characteristics of modeling ----------------------------------- No thermal or mechanical calculation is carried out in this test: the stress reading tables are directly provided to operator POST_RCCM. Type EVOLUTION and type B3200 results are analyzed for options FATIGUE_ZH210 and FATIGUE respectively. Option EFAT is analyzed with type B3200. Tested sizes and results ------------------------------ On this simple test case, all the results tested are in agreement with the reference solution: * for the calculation of Sp, Salt and elementary and cumulative damage, * for a pipe junction, * with and without an earthquake, * with TYPE_KE = 'KE_MECA' and 'KE_MIXTE' * the environment factor and the elastic environment factor * the use factor with environmental fatigue, * with option TYPE_RESU =' VALE_MAX 'as with option TYPE_RESU =' DETAILS '. Analytical solution with less than :math:`{10}^{-4}` percent accuracy.