3. Modeling A#
3.1. Characteristics of modeling#
No thermal or mechanical calculation is carried out in this test: the stress reading tables are directly provided to operator POST_RCCM. Type EVOLUTION and B3200 results are analyzed for option PM_PB.
3.2. Tested sizes and results#
On this simple test case, all the results tested are in agreement with the reference solution:
for the calculation of Pm, Pb and PmPb,
for a pipe junction,
with and without an earthquake,
with the options TYPE_RESU =” VALE_MAX “, TYPE_RESU =” DETAILS”, and TYPE_RESU =” SYSTUS “(fatigue only for this last option).
Analytical solution with less than \({10}^{-4}\) percent accuracy.